PowIRCenter Release Notes March 05th, 2020. Version V1.0.7369 -- The USBXpress device driver has been upgraded to v6.7.2.0 and SiUSBXp.dll is upgraded to v6.7.5.(0). -- Changes to the Acadia (IR35215) and Acadie (TDA11280A): Added note in the register map for the "ICCMAX" that the value setting NOT to be less than 9A for both loops. Added to the config checker and set flag if it is set to less than 9A. February 10th, 2020. Version V1.0.7345 General -- Fixed crash issue while launching Fault and Protection tool in Acadia controller -- Fixed manhattan communication bug when auto write is enabled caused by 1. writing 0 to i2c address 2. replacing 38165 with 38163 -- Added SCL low 35ms in i2c debugger -- Changed comanche ripple calculator to 500A -- Fixed acadia protection gui is not synced to register -- [AcadiaR2]-PIRCGUI-459 - Check MTP in the Device Programmer was causing the dongle to lock up. This is because the Check was using UsbTxRxFast which was ignoring the fact that another transaction may already be in progress. -- All - PIRCGUI-455. Fixed the issue in Acadia Protection design tool where the TrackBar was settings its value to itself, causing the value to never change. -- AcadiaR2 RegisterMap - Added code handle loading a read-only configuration file. -- AcadiaR2 Register Map - Read All Registers was not returning data correctly because Telemetry Update would overwrite returned data. Had to fix it by stopping the Timer that controlled Telemetry Update whenever we execute a I2C command. -- AcadiaR2 PMBus D5h - PIRCGUI-460. The GUI was resulting with no description for command D5h -- All PMBus - PIRCGUI-459. Every time the user selects the Device Level and then the Loop Level, the description was re-adding to the PMBus Commands controls.(Code - 80, D6, D8, DD, DE, D5) -- Acadia - fix register read/write error caused by prebias ovp checking. July 23rd, 2019. Version V1.0.7143 General -- When trying to set a Numeric Up Down control value, the value is capped at the maximum & minimum. This should prevent errors when trying to load or set values outside the range. -- Firmware version updated to v59 AcadiaR2 -- Design Tools ---- Current Synthesis ------ Inductance was not being synced between the register value and the model value. We now restore the inductance value from the register lX_inductance_reciprocal. ---- Protection ------ IccMax will now properly write to the loop-specific register icc_max in SVID mode. ---- Register Map ------ Added a 5ms delay after low-level reads and writes. Without the delay, this would cause communication issues when reading and writing a large number of registers. ------ Register map description for loop_1_phase1_thresh and loop_2_phase1_thresh was incorrect. The formula had a "-3" as part of the calculation which should not be there. ------ Changed the unit for the decoded value of PMBus Command VOUT_DROOP from "Ohm" to "mOhm". ------ Package Config dialog now writes to the register when the user successfully clicks "Save Settings" ManhattanSVID -- Design Tools ---- Iout Telemetry Correction has been removed from the list of Design Tools -- Register Map ---- Removed the correction factor entry from the Save Configuration File flow. User can still enter Project Name. Rocky -- Design Wizard ---- Added 5 new design macros ------ Cyclone 5V 10CL016 ------ Cyclone CL00 to CL25 ------ Cyclone CL40 to CL120 ------ Zynq 7 7010 – 7030 ------ Spartan 7